Extron Electronics, Europe
Beeldschermweg 6C, 3821 AH Amersfoort
The Netherlands
+800.3987.6673 +31.33.453.4040
FAX +31.33.453.4050
Extron Electronics, Asia
135 Joo Seng Rd. #04-01
PM Industrial Bldg.
Singapore 368363
+65.6383.4400 FAX +65.6383.4664
Extron Electronics, Japan
Kyodo Building, 16 Ichibancho
Chiyoda-ku, Tokyo 102-0082
Japan
+81.3.3511.7655 FAX +81.3.3511.7656
Extron Electronics, USA
1230 South Lewis Street
Anaheim, CA 92805
800.633.9876 714.491.1500
FAX 714.491.1517
DESCRIPTION SPECIfICaTIONS
aPPlICaTION DIagRam
Specifications are subject to change without notice.
© 2007 Extron Electronics. All rights reserved. All trademarks mentioned are the property of their respective owners.
07-05
68-1424-01
REV. A
10
0
-
1
2
0V
50
/6
0
H
z
15
A
MA
X
P
O
W
E
R
O
U
T
P
U
T
15
A
M
A
X
LA
N
C
O
M
T
X
I
N S
G
+
5
V
R
X
I
N
P
U
T
I
R
TCP/IP
Network
O
N
Ethernet
DVD
AC Power
RS-232
Plasma
Display
Remote User
Control &
Administrator
Monitoring
Extron
IR Emitter
Kiosk
Button
Extron
IPL T PC1
Ethernet Control
Interface
The Extron IPL T PC1 and IPL T PC1i AC Power and Device Controllers
with IP Link
®
feature a single AC power outlet, RS-232, an IR output and
a contact closure input. Both models include Extron IP Link technology,
enabling flexible, centralized, Web-based power and device management.
The IPL T PC1 supplies up to 12 A of 120 VAC power, using an Edison
outlet. The IPL T PC1i supplies up to 10 A of 220 VAC power, using an IEC
outlet. They can be used to cycle power to a “frozen” A/V device or be
configured to turn the device ON or OFF at scheduled times for security
and energy savings. For real time notification, the controller can be
programmed to send out an e-mail when each event is performed.
Web-based A/V device management is further enhanced by the RS-232
and IR ports which can be used to remotely control the operation of a
DVD player, VCR, or display.
The contact closure input port can be connected to a switch or sensor
for theft detection or automated device control. The software can be
configured to trigger a user-definable action when the input senses a drop
in voltage, such as sending an email when a device is disconnected or
disabling the power outlet when a cabinet is opened.
The IPL T PC1 Series controllers can be configured using Extron’s easy-to-
use free configuration software, Global Configurator. The IPL T PC1 and
IPL T PC1i are easily integrated alongside other IP Link products and can
be remotely managed and controlled using the free GlobalViewer Web
application.
The integration of AC power control with device control in a single
enclosure, makes IPL T PC1 Series controllers ideal for a wide variety of
remote networked applications.
fEaTuRES
n Web-based remote AC power and device control and scheduling
n One AC outlet:
- 120 VAC 12 A Edison female, IPL T PC1
- 220 VAC 10 A IEC female, IPL T PC1i
n One bidirectional RS-232 serial port
n One IR port
n One contact closure input for detecting a switch closure
n E-mail notification enables proactive support
n Integral high-performance Web server
n AC outlet status is retained during power loss
n Front panel security lockout
n Supports industry standard Ethernet protocols
n Simultaneous multi-user support
n Multiple levels of access with password protection
n Free, easy-to-use Global Configurator software
Serial control interface
Serial control port .................................. (1) RS-232, 3.5 mm captive screw connectors,
4 pole
Baud rate and protocol ........................... 115200 to 300 baud (9600 baud = default) ;
8 (default) or 7 data bits; 1 (default) or 2 stop bits;
no parity (default), or even or odd parity
Serial control pin configurations.............. 1 = TX, 2 = RX, 3 = GND, 4 = +5 VDC
ethernet control interface
Connector .............................................. 1 RJ-45 female connector
Data rate ................................................ 10/100Base-T, half/full duplex with autodetect
Protocols................................................. ARP, DHCP, ICMP (ping), TCP/IP, UDP/IP, Telnet,
HTTP, SMTP
Default settings ....................................... Link speed and duplex level = autodetected
IP address = 192.168.254.254
Subnet mask = 255.255.0.0
Gateway = 0.0.0.0
DHCP = off
Web server .............................................. Up to 200 simultaneous sessions
7.25 MB nonvolatile user memory
Program control ..................................... Extron’s Simple Instruction Set (SIS
™
)
Global Viewer requirements .................... Microsoft
®
Internet Explorer ver. 6 or higher
contact cloSure control interface
Quantity/type ......................................... 1 contact closure input
Contact input control connector ............. (1) 3.5 mm captive screw connector, 4 pole
(shared with IR/serial output port)
Contact closure (input only)
Input voltage range .............................
0 to 5 VDC, clamped at +5.1 V
Input impedance .................................
10k ohms
Threshold ............................................
1.6 VDC
Pin configuration .................................... 1 = contact input, 2 = GND
ir control interface
IR control port ........................................ (1) 3.5 mm captive screw connector, 4 pole
(shared with contact closure port)
Pin configurations ................................... 3 = S (IR signal output), 4 = GND
IR output carrier frequency ..................... 30 kHz to 1 MHz
ac control interface
Connectors
IPL T PC1
............................................. 1 female USA/Edison power connector
IPL T PC1i ............................................
1 female IEC power connector
Voltage
IPL T PC1
............................................. 120 VAC, 50-60 Hz
IPL T PC1i ............................................
220 VAC, 50-60 Hz
Maximum AC load
IPL T PC1
............................................. 12 A, 1440 watts at 120 VAC
IPL T PC1i ............................................
10 A, 2200 watts at 220 VAC
General
Power input ........................................... 100 VAC to 240 VAC, 50/60 Hz, 5 watts, internal,
on 1 male IEC power connector
IPL T PC1 ................................................ 12 A (max.)
IPL T PC1i ............................................... 10 A (max.)
Cooling................................................... Convection, unvented
Rack mount ............................................ Yes, with optional 1U rack shelf, part #60-190-01
or 60-604-01; or 1U, 6" deep rack shelf,
part #60-190-10 or 60-604-10. Also furniture
mountable with optional VersaTools under desk
mounting kit, part #70-077-01.
Enclosure type ....................................... Metal
Enclosure dimensions ............................. 1.7" H x 4.3" W x 6.0" D (1U high, quarter rack
wide) 4.3 cm H x 10.9 cm W x 15.2 cm D
(Depth excludes connectors.)
Product / Shipping weight ...................... 1.0 lbs (0.5 kg) / 3 lbs (2 kg)
Listings ................................................... UL, CUL pending
Compliances ........................................... CE, FCC Class A, VCCI, AS/NZS, ICES
MTBF ...................................................... 30,000 hours
Warranty ................................................ 3 years parts and labor
NOTE: All nominal levels are at ±10%.
Model Version Description Part Number
IPL T PC1 120 VAC Edison
....................................................... 60-544-10
IPL T PC1i 220 VAC IEC
............................................................ 60-544-20
Comentários a estes Manuais