MTP T 15HD A Architectural Series • Installation 6
5. With the power supply disconnected, feed cables for the output devices through the
opening and through the wall box punch-out holes, securing them with cable clamps to
provide strain relief.
6. Trim back, insulate, or do both to exposed cable shields with heat shrink to reduce the
chance of short circuits.
a. To prevent short circuits, the outer foil shield can be cut back to the point where the
cable exits the cable clamp.
b. Both braided and foil shields should be connected to an equipment ground at the
other end of the cable.
7. Connect the output device cables to the rear of the MTP architectural wall plate (see
Twisted Pair Cable Termination on page 13 for connector wiring details).
8. Connect input devices (see Front Panel Features on page 9 for connector details),
restore the power supply, and test the wall plate. Make any cabling adjustments before
final installation as the cables will be inaccessible afterwards.
Installing into a Mud Ring (WM and Decora Models)
1. Using the mud ring as a guide, mark the edges and cut out the material within the
marked area.
2. Insert the mud ring into the opening, rotate the arms, and secure with the supplied
screws.
3. Follow steps 5 through 8 of Preparing the Site and Installing the Wall Box above,
and Final Installation on page 7.