Command
ASCII Command
(Host to SCP)
Hex
(Host to SCP)
Response
(SCP to Host)
Additional Description
Information Requests
Query firmware version
q 71
X!
]
Show current firmware version
X!
.
Query firmware version —
factory and updated
0q 30 71
x.xx, y.yyy
]
x.xx = factory firmware version
number format.
y.yyy = updated firmware
version number format.
Example
0q 30 71
1.00, 1.01
]
The factory version is 1.00; the
updated version is 1.01.
Query firmware version —
factory
q or 1q 31 71
x.xx
]
Query firmware version —
updated
2q 32 71
y.yy
]
Query part number
n 6E
60-671-nn
]
or
60-672-nn
]
60-671-nn = SCP 226
60-672-nn = SCP 104
Query model name and
description
i
69
SCPnnn
]
nnn = 104 or 226
Command and Response Table for SIS Commands