Extron electronics SW12 VGA Ars Instruções de Operação Página 25

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 41
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 24
SW8/12 VGA Ars • Control
3-2
Control
Remote Control via Simple Instruction Set (SIS
)
TheSW8/12VGAArsswitcherscanbecontrolledviaRS-232usingExtron’sSimple
InstructionSet(SIS)commands.
TheRS-232portcommunicationsprotocolsare:9600baud,8databits,1stopbit,
no parity, and no flow control. Cable pinouts are shown in the table below.
Onlypins2,3,and5arerequired.Disconnectallotherconductorsinthe
attachment cable for proper operation.
Pin RS-232 Description RS-232 Control Port Connector
1
DB9 Pin Locations
Female
51
96
2 Tx Transmit data
3 Rx Receive data
4
5 Gnd Signal ground
6
7
8
9
RulesgoverningSIScommandsinclude:
• SIScommandsconsistofoneormorecharacterspereld.
• Nospecialcharactersarerequiredtobeginorendacommandsequence.
• Whenacommandisvalid,theswitcherexecutesthecommandandsendsa
response to the host device.
• Allresponsesfromtheswitchertothehostendwithacarriagereturnanda
linefeed(CR/LF=
]
), which signals the end of a response character string.
• Astringisoneormorecharacters.
Switcher-initiated (unsolicited) messages
When a local event, such as a front panel operation or error condition, occurs, the
switcher responds by sending a message to the host. Switcher-initiated messages
are listed below:
(C) Copyright 2008, Extron Electronics SWy VGA Ars, Vx.xx
]
Theswitcherissuesthecopyrightmessagewhenitrstpowerson.
y = the number of inputs (8 or 12, depending on the model)
x.xx
=thermwareversionnumber
Vista de página 24