Extron-electronics Annotator User Guide Manual do Utilizador Página 65

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 108
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 64
Command ASCII (Telnet)
(host to processor)
URL Encoded (Web)
(host to processor)
Response
(processor to host)
Additional description
Configure redirect mode
EX12%
*
X14#
*
X14$
*
X13!
CD
}
WX12%%2AX14#%2AX14$
%2A
X13!CD|
Cpn
X12%•
Ccd
X14#
,
X14$
,
X13!]
Terminate redirect mode
EX12%
*0CD
}
WX12%%2A0CD|
Cpn
X12%•
Ccd00000,00000,
00000L
]
Read redirect mode
EX12%
CD
}
WX12%CD|
X14#
,
X14$
,
X13!]
Ethernet data port
Set current conn port time-out
E0
*
X14@
TC
}
W0%2AX14@TC|
Pti0*
X14@]
Read current conn port time-
out
E0
TC
}
W0TC|
X14@]
Set global IP port time-out
E1
*
X14@
TC
}
W1%2AX14@TC|
Pti1*
X14@]
Read global IP port time-out
E
1TC
}
W1TC|
X14@]
Directories
Change/create directory
Epath/directory/
CJ
}
Wpath/directory/%2FCJ|
Dir
path/directory/
]
Back to root directory
E/
CJ
}
W%2FCJ|
Dir
/]
Up one directory
E~
CJ
}
W%2E%2ECJ|
Dir
path/directory/
]
View current directory
E
CJ
}
WCJ|
path/directory/
]
directory = A text string drawn from the alphabet (A-Z), digits (0-9), minus sign/hyphen (-). No blank or space characters are permitted as part of the name.
No distinction is made between upper and lower case. The first character must be an alpha character.
NOTE: A directory does not truly exist until a le has been copied into that path.
Unlike various PC operating systems, a le and directory on the Extron product are allowed to have the same name.
The current directory is a per-connection setting. It begins at the root for each IP session.
NOTE: X12% = specic serial port number (01-03), 01 = COM1 (rear panel, bottom port), 02 = COM2 (front panel cong port), 03 = COM3 (rear panel, top
port)
X13! = Parameter (#L or #D) to set either the Length of message to receive or the Delimiter value. # = byte count (for L) or # = a single ASCII character
expressed in decimal form (for D). The parameter is case sensitive. Byte count is 0 to 32767 (default = 0.)
X14@ = IP connection time-out period specied in 10-second steps , 1 - 65000 (default = 30 = 300 seconds). If no data is received in the specied period,
the connection closes.
X14# = Redirection status: 0 = no redirection, 1 - 3 = redirect serial communication to COM1, COM2,or COM3
X14$ = Time-out period in tens of milliseconds for serial data pass-through mode, range = 1 - 32767 (default = 10 = 100 ms)
Annotator • SIS Communication and Control 59
Vista de página 64
1 2 ... 60 61 62 63 64 65 66 67 68 69 70 ... 107 108

Comentários a estes Manuais

Sem comentários