Extron electronics MPX 423 A Instruções de Operação Página 24

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 56
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 23
MPX 423 A • Operation
Operation, cont’d
Mode 3: Holding the Reset button until the I/O LED blinks once (3 seconds)
followed by a momentary (<1 second) press turns events either on or off,
depending on the current state of the events:
If the events are currently stopped following the momentary (<1 second)
press, the I/O LED will flash twice indicating the starting of events.
or
If events are currently running following the momentary (<1 second)
press, the I/O LED flashes three times, indicating the stopping of events.
Each flash lasts for .25 seconds. Nothing happens if the momentary press
does not occur within 1 second.
Mode 4: Holding the Reset button until the I/O LED
blinks twice (6 seconds)
followed by a momentary (<1 second) press will reset IP settings. The I/O
LED blinks four times in quick succession, confirming a Mode 4 reset. This
mode
1. Enables ARP program capability
2. Sets IP back to factory IP
3. Sets Subnet back to factory default
4. Sets Gateway back to factory default
5. Sets port mapping back to factory default
6. Turns DHCP off
7. Turns events off
Nothing happens if the momentary press does not occur within one second.
Mode 5: Holding the Reset button until the I/O LED
blinks three times
(9 seconds) followed by a momentary (<1 second) press causes a complete
system reset back to factory default conditions. Nothing happens if the
momentary press does not occur within 1 second. The I/O LED blinks four
times in quick succession, confirming a Mode 5 reset.
Factory reset modes
Factory resets can be set using the front panel I/O button. To reset the MPX 423 A
to factory defaults
1. Press and hold the I/O button on the front panel while plugging in AC power.
2. Continue to hold the I/O button until all LEDs on the front panel flash.
Once the I/O button is released, power-up continues and the LEDs go back to their
default configuration.