MPX 423 A • Programmer’s Guide
Error responses
When the MPX 423 A matrix switcher receives an SIS command and
determines that it is valid, it performs the command and sends a response to
the host device. If the switcher is unable to perform the command because
the command is invalid or contains invalid parameters, it returns an error
response to the host. The error response codes are:
E01 Invalid input channel number
E10 Invalid command
E11
Invalid preset number
E12
Invalid output number / Invalid port number
E13 Invalid parameter
E14 Command not available for matrix configuration
E17 Timeout (only caused by direct write of global presets)
E22 Busy
E24 Privilege violation (Ethernet, Extron software only) User
privileges have access to ALL view and read commands, and
the following:
Create Ties
Create and Recall Presets
Set RGB and Audio Mutes
Exception to the rule: User cannot read Admin Password
E25 Device not present
E26 Maximum number of connections exceeded
E27 Invalid Event number
E28 Bad Filename / File not found
References to errors
24
= Commands that give E24 (privilege violation) if not administrator level.
Copyright information
(c) Copyright 2004, Extron Electronics, MPX 423 A, V
x.xx
The copyright message is initiated by the MPX 423 A matrix switcher when it
is first powered on. Vx.xx is the firmware version number.
5-5