WindoWall Pro Series • Remote Configuration and Control 36
X12$
= Daylight saving time (used in the North America
and parts of Europe and Brazil)
0 = off or ignore
1 = on in northern hemisphere
2 = on in Europe
3 = on in Brazil
X13)
= Read password. RS-232 or RS-422 connection
responds with the password. The IP connection
responds with 4 asterisks (****) if a password
exists, and with an empty space if none exists,
instead of with an actual password.
X13%
= Default name: a combination of the model-name and
the last three character pairs of the unit MAC address
(for example, WindoWall-Pro-00-02-3D)
X13&
= Connection security level
0 = anonymous
1-10 = extended security level
11 = user
12 = administrator
X13*
= (Ethernet only) Number of seconds (stated in tens of
seconds) before timeout on IP connections
Min = 1 (10 seconds),
Max = 65000 (650,000 seconds), and
Default = 30 (300 seconds)
If no data is received during the timeout period,
the Ethernet connection is closed. Each step is 10
seconds.
When the unit is connected via RS-232 or RS-422,
only the global timeout commands apply; anything
else returns an E13 error code. The response
contains leading zeros.