WindoWall Pro Series • Remote Configuration and Control 41
Command
ASCII (Telnet)
(Host to Processor)
URL Encoded (Web)
(Host to Processor)
Response
(Processor to Host)
Additional Description
Bi-directional Serial Data Port (continued)
Configure flow
control
24
E
X10!
*
X12!
,
X12@
CF
}
W
X10!
%02A
X12!
%02C
X12@
CF
|
Cpn
X10!
•C
X12!
,
X12@
]
Set flow control type
X12!
with
X12@
ms between bytes.
For
X12!
:
H = Hardware.
S = Software.
N = None (default).
X12@
= 0000 through 0001.
Default = 0 ms.
View flow control
E X10!
CF
}
W
X10!
CF
| X12! , X12@ |
Configure receive
timeout
24
E X10!
*
X10(
*
X11)
*
X11%
*
X11!
CE
}
W
X10!
%2A
X10(
%2A
X11)
%2A
X11%
%2A
X11!
CE
|
Cpn
X10!
•Cce
X10(
,
X11)
,
X11%
,
X11!
]
Set the time that the
WindoWall Pro will wait for a
response before terminating
the command.
NOTES:
X10!
= Port number (01-99)
X10@
= Command data section. For web encoding for
X10@
, be sure to convert non-alphanumeric characters to hex
numbers.
X10(
= Time in tens of milliseconds that the WindoWall Pro will wait until receipt of the first response character before
terminating the command. Default = 10 = 10 ms. Max. = 32767.
X11)
= Time in tens of milliseconds that the WindoWall Pro will wait between characters being received via a serial
port before terminating the current command or receive operation. Default = 20 = 20 ms. Max. = 32767.
X11!
= Message length #L or #D. The letter parameter is case sensitive (requires capital D or capital L).
L =Length of the message to be received.
D = Delimiter value. A delimiter of ASCII 0A = 10D.
# = Byte count (for L) or a single ASCII character expressed in decimal form (for D).
The byte count # can be 0-32767. Default = 0.
The ASCII decimal # can be 0-00255. Default = the byte count.
A 3-byte length = 3L. The response includes leading zeros.
X11%
= Priority status for port
X10!
receiving timeouts. For
X11%
:
0 = Use Send data string command parameters (default).
1 = Use Congure receive timeout command parameters.
The response includes leading zeros.
The *
X10(
*
X11)
*
X11!
sequence is optional. If
X10(
and
X11)
are not specified, the defaults are used.
View receive
timeout
E
X10!
CE
}
W
X10!
CE
| X10(
,
X11)
,
X11%
,
X11!
]