Extron-electronics SME 100 User Guide Manual do Utilizador Página 117

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 185
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 116
4. In the Sync to Matrix panel, select Enabled from the Enabled/Disabled radio
buttons (see figure 86).
4
5
6 7
8
9
EDID
Sync-To-Matrix
Advanced Settings
Figure 86. Advanced Settings Page — Sync-To-Matrix
5. Use the Video Out field to enter the number of the matrix switcher video output port
connected to the SME100.
6. Use the IP Address field to enter the IP address of the matrix switcher connected to
the SME100.
7. Use the Telnet Port field to enter the Telnet port of the matrix switcher connected to
the SME100. The default is 23.
8. If a password is needed to access the matrix switcher connected to the SME100, use
the Password (if req.) field to enter the password.
9. Click the Submit button to save the configuration settings and sync the SME100 to the
matrix switcher.
NOTES:
If the SME100 successfully syncs with the matrix switcher, the Status field will
display Connected.
If the Status field continues to display Not Connected, check the settings of
the matrix switcher and the SME100 and try resyncing the devices.
SME100 • Web-based Configuration Page 111
Vista de página 116
1 2 ... 112 113 114 115 116 117 118 119 120 121 122 ... 184 185

Comentários a estes Manuais

Sem comentários